Arp U, Clark C.W, Farrell A.P, Fein E, Furst M.L, Hagley E.W. Synchrotron ultraviolet radiation facility SURF III. Review of Scientific Instruments. 2003;73:1674–1676.
Aruev P.N, Kolokolnikov Y.M, Kovalenko N.V, Legkodymov A.A, Lyakh V.V, Nikolenko A.D, Pindyurin V.F, Sukhanov V.L, Zabrodsky V.V. Characterization of spatial homogeneity of sensitivity and radiation resistance of semiconductor detectors in the soft X-ray range. Nuclear Instruments and Methods in Physics Research A. 2009;603:58–61.
BenMoussa A, Hochedez J.-F, Schmutz W.K, Schühle U, Nesladek N, Stockmann Y, Kroth U, Richter M, Theissen A, Remes Z, Haenen K, Mortert V, Koller S, Halain J.P, Petersen R, Dominique M, D’Olieslaeger M. Solar-blind diamond detectors for LYRA, the solar VUV radiometer on Board Proba II. Experimental Astronomy. 2003;16:141–148.
BenMoussa A, Theissen A, Scholze F, Hochedez J.F, Schühle U, Schmutz W, Haenen K, Stockman Y, Soltani A, McMullin D, Vest R.E, Kroth U, Laubis C, Richter M, Mortet V, Gissot S, Delouille V, Dominique M, Koller S, Halain J.P, Remes Z, Petersen R, D'Olieslaeger M, Defise J.M. Performance of diamond detectors for VUV applications. Nuclear Instruments and Methods in Physics Research A. 2006;568:398–405.
Brendel M, Helbling M, Knigge A, Brunner F, Weyers M. Solar-blind AlGaN MSM photodetectors with 24 % external quantum efficiency at 0 V. Electronics Letters. 2015;51:1598. .
Canfield L.R, Vest R, Woods T.N, Korde R. Silicon photodiodes with integrated thin film filters for selective bandpasses in the extreme ultraviolet. In: Proc. SPIE. vol. 2282. 1994:31–38.
Geist J, Liang E, Schaefer A.R. Complete collection of minority carriers from the inversion layer in induced junction diodes. Journal of Applied Physics. 1981;52:4879–4881.
Gerlach M, Krumrey M, Cibik L, Müller P, Ulm G. A cryogenic electrical substitution radiometer for hard X-rays. Nuclear Instruments and Methods in Physics Research A. 2007;580:218–221.
Gottwald A, Kroth U, Krumrey M, Richter M, Scholze F, Ulm G. The PTB high-accuracy spectral responsivity scale in the VUV and x-ray range. Metrologia. 2006;43:S125–S129.
Gottwald A, Kroth U, Richter M, Schöppe H, Ulm G. Ultraviolet and vacuum-ultraviolet detector-based radiometry at the metrology light source. Measurement Science and Technology. 2010;21:125101,. doi: 10.1088/0957-0233/21/12/125101.
Gottwald A, Richter M, Shaw P.-S, Li Z, Arp U. Bilateral NIST–PTB comparison of spectral responsivity in the VUV. Metrologia. 2011;48:02001.
Gullikson E.M, Korde R, Canfield L.R, Vest R.E. Stable silicon photodiodes for absolute intensity measurements in the VUV and soft x-ray regions. Journal of Electron Spectroscopy and Related Phenomena. 1996;80:313–316.
Hartmann R, Hauff D, Lechner P, Richter R, Strüder L, Scholze F, Ulm G. Low energy response of silicon pn-junction detectors. Nuclear Instruments and Methods in Physics Research A. 1996;377:191–196.
Henke B.L, Gullikson E.M, Davis J.C. X-ray interactions: photoabsorption, scattering, transmission, and reflection at E = 50-30000 eV, Z = 1-92. Atomic Data and Nuclear Data Tables. July 1993;54(2):181–342 online. http://www-cxro.lbl.gov.
Henneken H, Scholze F, Ulm G. Lack of proportionality of total electron yield and soft x-ray absorption coefficient. Journal of Applied Physics. 2000;87:257–268.
Kalinina E.V, Violina G.N, Belik V.P, Nikolaev A.V, Zabrodskii V.V. Quantum efficiency of 4H-SiC detectors within the range of 114-400 nm. Technical Physics Letters. 2016;42:1057–1059.
Klein R, Krumrey M, Richter M, Scholze F, Thornagel R, Ulm G. Radiometry with synchrotron radiation at the PTB laboratory at BESSY II. Synchrotron Radiation News. 2002;15:23–29.
Klein R, Thornagel R, Ulm G, Feikes J, Wüstefeld G. Status of the metrology light source. Journal of Electron Spectroscopy and Related Phenomena. 2011;184:331–334.
Korde R, Geist J. Quantum efficiency stability of silicon photodiodes. Applied Optics. 1987;26:5284–5290.
Korde R, Geist J. Stable, high quantum efficiency silicon photodiodes by arsenic diffusion. Solid State Electron. 1987;30:89–92.
Korde R, Cable J.S, Canfield L.R. One gigarad passivating nitrided oxides for 100% internal quantum efficiency silicon photodiodes. IEEE Transactions on Nuclear Science. 1993;40:1655–1659.
Korde R, Prince C, Cunningham D, Vest R.E, Gullikson E. Present status of radiometric quality silicon photodiodes. Metrologia. 2003;40:S145–S149.
Kurlbaum F. Notiz über eine Methode zur quantitativen Bestimmung der stahlenden Wärme. Annals of Physics. 1894;287:591. .
Malinowski P.W, Duboz J.-Y, De Moor P, Minoglou K, John J, Horcajo S.M, Semond F, Frayssinet E, Verhoeve P, Esposito M, Giordanengo B, BenMoussa A, Mertens R, Van Hoof C. ‘Extreme ultraviolet detection using AlGaN-on-Si inverted Schottky photodiodes’. Applied Physics Letters. 2011;98:141104.
Martin J.E, Fox N.P, Key P.G. A cryogenic radiometer for absolute radiometric measurements. Metrologia. 1985;21:147–155.
Nanver L.K. Silicon photodiodes for low penetration depth beams such as DUV/VUV/EUV light and low-energy electrons ISBN: 978-953-307-163-3. In: Franco Dalla Betta G, ed. Advances in Photodiodes. Rijeka, Croatia: InTech Europe University Campus; 2011 Available from:. http://www.intechopen.com/articles/show/title/silicon-photodiodes-for-low-penetration-depth-beams-such-as-duv-vuv-euv-light-and-low-energy-electrons InTech Europe, 51000 Rijeka, Croatia.
Optodiode. http://www.optodiode.com/pro_09.html Brochure Download at: http://www.irdinc.com/brochure/IRD2011.pdf, pp. 15.
Palik E.D. Handbook of Optical Constants of Solids. San Diego, New York, Boston, London, Sydney, Tokyo, Toronto: Academic Press, Inc.; 1985.
Rabus H, Persch V, Ulm G. Synchrotron-radiation operated cryogenic electrical-substitution radiometer as high-accuracy primary detector standard in the ultraviolet, vacuum ultraviolet and soft x-ray spectral ranges. Applied Optics. 1997;36:5421–5440.
Rabus H, Klein R, Scholze F, Thornagel R, Ulm G. Validation of the uncertainty budget for soft X-ray radiant power measurement using a cryogenic radiometer. Metrologia. 2002;39:381–389.
Rügheimer T.K, Gebert U, Michel T, Anton G, Seguinot J, Joram C. Experimental demonstration of a hybrid photon detector concept based on the Timepix detector. Nuclear Instruments and Methods in Physics Research A. 2008;595:353–358.
Saito T, Onuki H. Design and performance of a beamline for VUV detector calibration. Journal of the Spectroscopical Society of Japan. 1992;43:385–393.
Scholze F, Procop M. Modelling the response function of energy dispersive x-ray spectrometers with silicon detectors. X-ray Spectrometry. 2009;38:312–321.
Scholze F, Rabus H, Ulm G. Spectral responsivity of silicon photodiodes: high-accuracy measurement and improved self-calibration in the soft x-ray spectral range. In: Proc. SPIE. vol. 2808. 1996:534–543.
Scholze F, Rabus H, Ulm G. Mean energy required to produce an electron-hole pair in silicon for photons of energies between 50 and 1500 eV. Journal of Applied Physics. 1998;84:2926–2939.
Scholze F, Henneken H, Kuschnerus P, Rabus H, Richter M, Ulm G. Determination of the electron-hole pair creation energy for semiconductors from the spectral responsivity of photodiodes. Nuclear Instruments and Methods in Physics Research A. 2000;439:208–215.
Scholze F, Brandt G, Müller P, Meyer B, Scholz F, Tümmler J, Vogel K, Ulm G. High-accuracy detector calibration for EUV metrology at PTB. In: Proc. SPIE. vol. 4688. 2002:680–689.
Scholze F, Klein R, Bock T. Irradiation stability of silicon photodiodes for extreme-ultraviolet radiation. Applied Optics. 2003;42:5621–5626.
Scholze F, Vest R, Saito T. Report on the CCPR pilot comparison: spectral responsivity 10 nm to 20 nm. Metrologia. 2010;47:02001. .
Schühle U, Hochedez J.-F. Solar-blind UV detectors vol. 9 of ISSI Scientific Report Series. In: Huber M.C.E, Pauluhn A, Culhane J.L, Timothy J.G, Wilhelm K, Zehnder A, eds. Observing Photons in Space —A Guide to Experimental Space Astronomy. second ed. Heidelberg: Springer; 2013:467–477 ISBN 978-1-4614-7803-47.
Schühle U. Intensified solid state sensor cameras: ICCD and IAPS vol. 9 of ISSI Scientific Report Series. In: Huber M.C.E, Pauluhn A, Culhane J.L, Timothy J.G, Wilhelm K, Zehnder A, eds. Observing Photons in Space —A Guide to Experimental Space Astronomy. second ed. Heidelberg: Springer; 2013:455–465 ISBN 978-1-4614-7803-47.
Seely J.F, Korde R, Hanser F, Wise J, Holland G.E, Weaver J, Rife J.C. Characterization of silicon photodiode detectors with multilayer filter coatings for 17–150 A. In: Proc. SPIE. vol. 3764. 1999:103–109.
Shi L, Sarubbia F, Nanver L.K, Kroth U, Gottwald A, Nihtianov S. Optical performance of b-layer ultra-shallow-junction silicon photodiodes in the VUV spectral range. Procedia Engineering. 2010;5:633–636.
Shi L, Nanver L.K, Nihtianov S.N. Stability characterization of high-sensitivity silicon-based EUV photodiodes in a detrimental industrial environment. In: IECON 2011 – 37th Annual Conference on IEEE Industrial Electronics Society, 7–10 November 2011, Melbourne, Australia. 2011:2651–2656.
Solt K, Melchior H, Kroth U, Kuschnerus P, Persch V, Rabus H, Richter M, Ulm G. PtSi-n-Si Schottky-barrier photodetectors with stable spectral responsivity in the 120–250 nm spectral range. Applied Physics Letters. 1996;69:3662–3664.
Tanaka T, Kato M, Kurosawa T, Morishita Y, Saito N, Suzuki I.H, Krumrey M, Scholze F. First comparison of spectral responsivity in the soft x-ray region. Metrologia. 2012;49:501–506.
Treis J, Fischer P, Halker O, Harter M, Herrmann S, Kohrs R, Kruger H, Lechner P, Lutz G, Peric I, Porro M, Richter R.H, Struder L, Trimpl M, Wermes N. DEPMOSFET active pixel sensor prototypes for the XEUS wide field imager. IEEE Transactions on Nuclear Science. 2005;52:1083–1091.