Note: Not all of the configuration items that are described in this chapter are necessarily required for your installation. Also, the examples that are presented are not intended to be exhaustive.
|
+---------------------------- Add Switch ----------------------------+
| |
| |
| Specify or revise the following values. |
| |
| Switch ID . . . . . . . . 41 (00-FF) |
| Switch type . . . . . . . 2032_________ + |
| Serial number . . . . . . __________ |
| Description . . . . . . . ITSO test SAN definition________ |
| Switch address . . . . . 41 (00-FF) for a FICON switch |
| |
| Specify the port range to be installed only if a larger range |
| than the minimum is desired. |
| |
| Installed port range . . 00 - FE + |
| |
| Specify either numbers of existing control unit and device, or |
| numbers for new control unit and device to be added. |
| |
| Switch CU number(s) . . . 0041 ____ ____ ____ ____ + |
| Switch device number(s) . 0041 ____ ____ ____ ____ |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+--------------------------------------------------------------------+
|
Switch List Row 1 of 3 More: >
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more switches, then press Enter. To add, use F11.
CU Dev
/ ID Type + Ad Serial-# + Description Num. Num.
_ 01 2032 01 10546MH 8960-F64 SAN64B-6 SW 01 0001 0001
_ 02 2032 02 10546MD 8960-F64 SAN64B-6 SW 03 0002 0002
_ 41 2032 41 __________ ITSO test SAN definition 0041 0041
******************************* Bottom of data *******************************
+---------------------------------------------------------------------+
| Switch control unit(s) 0041 and device(s) 0041 defined, but not yet |
| connected to both a processor and an operating system. |
+---------------------------------------------------------------------+
|
+---------------------------- Add Channel Path -----------------------------+
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| Configuration mode . : LPAR |
| Channel Subsystem ID : 2 |
| |
| Channel path ID . . . . 14 + Channel ID 114 + |
| Number of CHPIDs . . . . 1 |
| Channel path type . . . FC + |
| Operation mode . . . . . SHR + |
| Managed . . . . . . . . No (Yes or No) I/O Cluster ________ + |
| Description . . . . . . FC#0428 16Gb FICON Exp16S+ SX |
| |
| Specify the following values only if connected to a switch: |
| Dynamic entry switch ID 41 + (00 - FF) |
| Entry switch ID . . . . 41 + |
| Entry port . . . . . . . 10 + |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+---------------------------------------------------------------------------+
|
+--------------------------- Define Access List ----------------------------+
| Row 1 of 1 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one or more partitions for inclusion in the access list. |
| |
| Channel subsystem ID : 2 |
| Channel path ID . . : 14 Channel path type . : FC |
| Operation mode . . . : SHR Number of CHPIDs . . : 1 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 2 MUSCA21 1 OS MUSCA21 test OS partition |
| **************************** Bottom of data ***************************** |
| |
| |
| |
| F1=Help F2=Split F3=Exit F5=Reset F6=Previous |
| F7=Backward F8=Forward F9=Swap F12=Cancel |
+---------------------------------------------------------------------------+
|
Channel Path List Row 1 of 1 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more channel paths, then press Enter. To add use F11.
Processor ID . . . . : MUSCA Musca
Configuration mode . : LPAR
Channel Subsystem ID : 2
CHID+ Dyn Entry +
/ CHPID AID/P Type+ Mode+ Sw+ Sw Port Con Mng Description
_ 14 114 FC SHR 41 41 10 No FC#0428 16Gb FICON Exp16S+ SX
******************************* Bottom of data *****************************
|
Note: For FC#0428 FICON Express16S+, defining FC and FCP CHPID types on the same I/O card is not supported. HCD issues the following warning message during a Validate or Build Production for an IODF:
W CBDA963I Chpid type mix detected on processor MUSCA for channels:
0.29, 0.31, 0.30, 0.44
|
+---------------------------- Add Channel Path -----------------------------+
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| Configuration mode . : LPAR |
| Channel Subsystem ID : 2 |
| |
| Channel path ID . . . . 15 + Channel ID 115 + |
| Number of CHPIDs . . . . 1 |
| Channel path type . . . FC_ + |
| Operation mode . . . . . SHR + |
| Managed . . . . . . . . No (Yes or No) I/O Cluster ________ + |
| Description . . . . . . FC#0428 16Gb FICON Exp16S+ SX___ |
| |
| Specify the following values only if connected to a switch: |
| Dynamic entry switch ID __ + (00 - FF) |
| Entry switch ID . . . . __ + |
| Entry port . . . . . . . __ + |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+---------------------------------------------------------------------------+
|
+--------------------------- Define Access List ----------------------------+
| Row 1 of 1 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one or more partitions for inclusion in the access list. |
| |
| Channel subsystem ID : 2 |
| Channel path ID . . : 15 Channel path type . : FC |
| Operation mode . . . : SHR Number of CHPIDs . . : 1 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 2 MUSCA21 1 OS MUSCA21 test OS partition |
| **************************** Bottom of data ***************************** |
| |
| |
| |
| F1=Help F2=Split F3=Exit F5=Reset F6=Previous |
| F7=Backward F8=Forward F9=Swap F12=Cancel |
+---------------------------------------------------------------------------+
|
Channel Path List Row 1 of 2 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more channel paths, then press Enter. To add use F11.
Processor ID . . . . : MUSCA Musca
Configuration mode . : LPAR
Channel Subsystem ID : 2
CHID+ Dyn Entry +
/ CHPID AID/P Type+ Mode+ Sw+ Sw Port Con Mng Description
_ 14 114 FC SHR 41 41 10 No FC#0428 16Gb FICON Exp16S+ SX
_ 15 115 FC SHR __ __ __ No FC#0428 16Gb FICON Exp16S+ SX
******************************* Bottom of data *****************************
|
Note: For FC#0428 FICON Express16S+, defining FC and FCP CHPID types on the same I/O card are not supported. HCD issues the following warning message during a Validate or Build Production for an IODF:
W CBDA963I Chpid type mix detected on processor MUSCA for channels:
0.29, 0.31, 0.30, 0.44
|
+----------------- Change Control Unit Definition ------------------+
| |
| |
| Specify or revise the following values. |
| |
| Control unit number . . . . A000 + |
| |
| Control unit type . . . . . 2107 + |
| |
| Serial number . . . . . . . __________ + |
| Description . . . . . . . . DS8886 - SU2 - SSID=A000 |
| |
| Connected to switches . . . 41 __ __ __ __ __ __ __ + |
| Ports . . . . . . . . . . . 11 __ __ __ __ __ __ __ + |
| |
| Define more than eight ports . . 2 1. Yes |
| 2. No |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+-------------------------------------------------------------------+
|
Select Processor / CU
+---------------------- Change Control Unit Definition -----------------------+
| |
| |
| Specify or revise the following values. |
| |
| Control unit number . : A000 Type . . . . . . : 2107 |
| Processor ID . . . . . : MUSCA Musca |
| Channel Subsystem ID . : 2 |
| |
| Channel path IDs . . . . 14 __ __ __ __ __ __ __ + |
| Link address . . . . . . 4111 ___ ____ ____ ____ ____ ____ ____ + |
| |
| Unit address . . . . . . 00 __ __ __ __ __ __ __ + |
| Number of units . . . . 256 ___ ___ ___ ___ ___ ___ ___ |
| |
| Logical address . . . . 40 + (same as CUADD) |
| |
| Protocol . . . . . . . . __ + (D, S or S4) |
| I/O concurrency level . _ + (1, 2 or 3) |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+-----------------------------------------------------------------------------+
|
Select Processor / CU
+------------------------- Modify Device Parameters -------------------------+
| Row 1 of 2 More: > |
| Command ===> __________________________________________ Scroll ===> CSR |
| |
| Specify or revise any changes to the device parameters in the list below. |
| To view attached control units, scroll to the right. |
| |
| Processor ID . . . . : MUSCA Musca |
| Channel Subsystem ID : 2 |
| |
| ---------Device--------- ---UA---- Preferred Exposure |
| No., Range Type SS+ Old New + Time-Out STADET CHPID + Device |
| A000,240 3390B _ 00 00 No Yes __ |
| A0F0,016 3390A 0 F0 F0 No Yes __ |
| ***************************** Bottom of data ***************************** |
| |
| |
| |
| |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F7=Backward F8=Forward F9=Swap F12=Cancel F20=Right |
| F22=Command |
+----------------------------------------------------------------------------+
|
Select Processor / CU Row 1 of 9 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select processors to change CU/processor parameters, then press Enter.
Control unit number . . : A000 Control unit type . . . : 2107
---------------Channel Path ID . Link Address + ---------------
/ Proc.CSSID 1------ 2------ 3------ 4------ 5------ 6------ 7------ 8------
_ MUSCA.2 14.4111 _______ _______ _______ _______ _______ _______ _______
_ CETUS.0 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.1 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.2 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.3 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.4 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.5 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.0 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.1 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.2 _______ _______ _______ _______ _______ _______ _______ _______
_ MUSCA.0 _______ _______ _______ _______ _______ _______ _______ _______
_ MUSCA.1 _______ _______ _______ _______ _______ _______ _______ _______
******************************* Bottom of data *****************************
|
Select Processor / CU
+---------------------- Change Control Unit Definition -----------------------+
| |
| |
| Specify or revise the following values. |
| |
| Control unit number . : A000 Type . . . . . . : 2107 |
| Processor ID . . . . . : MUSCA Musca |
| Channel Subsystem ID . : 2 |
| |
| Channel path IDs . . . . 14 15 __ __ __ __ __ __ + |
| Link address . . . . . . 4111 ____ ____ ____ ____ ____ ____ ____ + |
| |
| Unit address . . . . . . 00 __ __ __ __ __ __ __ + |
| Number of units . . . . 256 ___ ___ ___ ___ ___ ___ ___ |
| |
| Logical address . . . . 40 + (same as CUADD) |
| |
| Protocol . . . . . . . . __ + (D, S or S4) |
| I/O concurrency level . _ + (1, 2 or 3) |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+-----------------------------------------------------------------------------+
|
Select Processor / CU Row 1 of 9 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select processors to change CU/processor parameters, then press Enter.
Control unit number . . : A000 Control unit type . . . : 2107
---------------Channel Path ID . Link Address + ---------------
/ Proc.CSSID 1------ 2------ 3------ 4------ 5------ 6------ 7------ 8------
_ MUSCA.2 14.4111 15 _______ _______ _______ _______ _______ _______
_ CETUS.0 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.1 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.2 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.3 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.4 _______ _______ _______ _______ _______ _______ _______ _______
_ CETUS.5 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.0 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.1 _______ _______ _______ _______ _______ _______ _______ _______
_ LEPUS.2 _______ _______ _______ _______ _______ _______ _______ _______
_ MUSCA.0 _______ _______ _______ _______ _______ _______ _______ _______
_ MUSCA.1 _______ _______ _______ _______ _______ _______ _______ _______
******************************* Bottom of data *****************************
|
+------------------------- Change Device Definition --------------------------+
| |
| |
| Specify or revise the following values. |
| |
| Device number . . . . . . . : A000 (0000 - FFFF) |
| Number of devices . . . . . : 240 |
| Device type . . . . . . . . : 3390B |
| |
| Serial number . . . . . . . . __________ + |
| Description . . . . . . . . . ________________________________ |
| |
| Volume serial number . . . . . ______ + (for DASD) |
| |
| PPRC usage . . . . . . . . . . _ + (for DASD) |
| |
| Connected to CUs . A000 ____ ____ ____ ____ ____ ____ ____ + |
| |
| ENTER to continue. |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
+-----------------------------------------------------------------------------+
|
+---------------------- Device / Processor Definition -----------------------+
| Row 1 of 1 |
| Command ===> __________________________________________ Scroll ===> CSR |
| |
| Select processors to change device/processor definitions, then press |
| Enter. |
| |
| Device number . . : A000 Number of devices . : 240 |
| Device type . . . : 3390B |
| |
| Preferred Device Candidate List |
| / Proc.CSSID SS+ UA+ Time-Out STADET CHPID + Explicit Null |
| c MUSCA.2 _ 00 No Yes __ No ___ |
| ***************************** Bottom of data ***************************** |
| |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel |
| F22=Command |
+----------------------------------------------------------------------------+
|
+-------------------- Define Device Parameters / Features --------------------+
| Row 1 of 7 |
| Command ===> ___________________________________________ Scroll ===> CSR |
| |
| Specify or revise the values below. |
| |
| Configuration ID . : ITSOTEST ITSO test OSCONFIG for z14 ZR1 |
| Device number . . : A000 Number of devices : 240 |
| Device type . . . : 3390B |
| |
| Parameter/ |
| Feature Value + R Description |
| OFFLINE No Device considered online or offline at IPL |
| DYNAMIC Yes Device supports dynamic configuration |
| LOCANY Yes UCB can reside in 31 bit storage |
| WLMPAV Yes Device supports work load manager |
| READ-ONLY No Restrict access to read requests (SEC or NO) |
| SHARED Yes Device shared with other systems |
| SHAREDUP No Shared when system physically partitioned |
| ***************************** Bottom of data ****************************** |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F7=Backward F8=Forward F9=Swap F12=Cancel F22=Command |
+-----------------------------------------------------------------------------+
|
+-------------------- Assign/Unassign Device to Esoteric --------------------+
| Row 1 of 1 |
| Command ===> __________________________________________ Scroll ===> CSR |
| |
| Specify Yes to assign or No to unassign. To view devices already |
| assigned to esoteric, select and press Enter. |
| |
| Configuration ID : ITSOTEST ITSO test OSCONFIG for z14 ZR1 |
| Device number . : A000 Number of devices : 240 |
| Device type . . : 3390B Generic . . . . . : 3390 |
| |
| / EDT.Esoteric Assigned Starting Number Number of Devices |
| _ 00.ITSOESO1 Yes ____ ____ |
| ***************************** Bottom of data ***************************** |
| |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel |
| F22=Command |
+----------------------------------------------------------------------------+
|
+----------- Define Device to Operating System Configuration -----------+
| Row 1 of 34 |
| Command ===> _____________________________________ Scroll ===> CSR |
| |
| Select OSs to connect or disconnect devices, then press Enter. |
| |
| Device number . : A000 Number of devices : 240 |
| Device type . . : 3390B |
| |
| / Config. ID Type SS Description Defined |
| _ DBSV4SU4 MVS z/OS DB Server 4 |
| _ DBSV5SU4 MVS z/OS DB Server 5 |
| _ DBSV6SU4 MVS z/OS DB Server 6 |
| _ ITSO MVS All ITSO devices |
| _ ITSOTEST MVS ITSO test OSCONFIG for z14 ZR1 Yes |
| _ PERF4SU4 MVS z/OS Appl Server 4 |
| _ PERF5SU4 MVS z/OS Perf Server 5 |
| _ PERF6SU4 MVS z/OS Appl Server 6 |
| _ ZHLXDRVR MVS z/OS Helix Central Mgmt Image |
| _ ZMEDRVR MVS z/OS 2.1 ServerPak refresh |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset |
| F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel |
| F22=Command |
+-----------------------------------------------------------------------+
|