Note: Not all of the configuration items that are described in this chapter are necessarily required for your installation. Also, the examples that are presented are not intended to be exhaustive.
|
Note: The support of virtual functions, the allowed range of virtual functions, and support of PNETIDs depends on the processor type and support level. For more information, see Input/Output Configuration Program User’s Guide, SB10-7172. HCD offers prompts for virtual functions and ensures that the validation rules are fulfilled.
|
FUNCTION
|
Function type
|
|||||
HYL
|
ISM
|
RCE
|
ROCE
|
ROC2
|
ZEDC
|
|
PCHID
|
Yes
|
No
|
Yes
|
Yes
|
Yes
|
Yes
|
VCHID
|
No
|
Yes
|
No
|
No
|
No
|
No
|
PNETID
|
No
|
Yes
|
No
|
Yes
|
Yes
|
No
|
PORT
|
Yes
|
No
|
No
|
No
|
Yes
|
No
|
VF
|
Yes
|
Yes
|
No
|
Yes
|
Yes
|
Yes
|
Processor List Row 1 of 3 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more processors, then press Enter. To add, use F11.
/ Proc. ID Type + Model + Mode+ Serial-# + Description
_ CETUS 3906 M03 LPAR 0EE0F73906 Cetus
_ LEPUS 2965 N20 LPAR 0BB4B72965 Lepus
f MUSCA 3907 ZR1 LPAR 007A883907 Musca
|
PCIe Function List
Command ===> add____________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
|
*---------------------------- Add PCIe Function ----------------------------*
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| |
| Function ID . . . . . . 0040 |
| Type . . . . . . . . . ISM + |
| |
| Channel ID . . . . . . . . . . . 7F1 + |
| Port . . . . . . . . . . . . . . _ + |
| Virtual Function ID . . . . . . 1__ + |
| Number of virtual functions . . 1 |
| UID . . . . . . . . . . . . . . ____ |
| |
| Description . . . . . . . . . . ISM FID=0040 VFID=1 CHID=7F1____ |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------- Add/Modify Physical Network IDs ---------------------*
| |
| |
| If the Channel ID (CHID) is associated to one or more physical networks, |
| specify each physical network ID corresponding to each applicable |
| physical port. |
| |
| Physical network ID 1 . . PERFNET_________ |
| Physical network ID 2 . . ________________ |
| Physical network ID 3 . . ________________ |
| Physical network ID 4 . . ________________ |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------------- Define Access List ----------------------------*
| Row 22 of 31 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one partition for the access list. |
| |
| Function ID . . . . : 0040 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 1 MUSCA11 1 OS |
| _ 1 MUSCA12 2 OS |
| _ 1 MUSCA13 3 OS |
| _ 1 MUSCA14 4 OS |
| _ 1 MUSCA15 5 OS |
| _ 1 MUSCA16 6 OS |
| _ 1 MUSCA17 7 OS |
| _ 1 MUSCA18 8 OS |
| _ 1 MUSCA19 9 OS |
| _ 2 MUSCA2A A CF MUSCA2A test CF partition |
| **************************** Bottom of data ***************************** |
| |
| |
| |
*---------------------------------------------------------------------------*
|
PCIe Function List Row 1 of 21 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 0040 7F1 _ 1 ISM ____ ISM FID=0040 VFID=1 CHID=7F1
|
PCIe Function List Row 1 of 24 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 0040 7F1 _ 1 ISM ____ ISM FID=0040 VFID=1 CHID=7F1
_ 0041 7F1 _ 2 ISM ____ ISM FID=0041 VFID=2 CHID=7F1
_ 0050 7F2 _ 1 ISM ____ ISM FID=0050 VFID=1 CHID=7F2
_ 0051 7F2 _ 2 ISM ____ ISM FID=0051 VFID=2 CHID=7F2
|
Processor List Row 1 of 3 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more processors, then press Enter. To add, use F11.
/ Proc. ID Type + Model + Mode+ Serial-# + Description
_ CETUS 3906 M03 LPAR 0EE0F73906 Cetus
_ LEPUS 2965 N20 LPAR 0BB4B72965 Lepus
f MUSCA 3907 ZR1 LPAR 007A883907 Musca
|
PCIe Function List
Command ===> add____________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
|
*---------------------------- Add PCIe Function ----------------------------*
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| |
| Function ID . . . . . . 00A2 |
| Type . . . . . . . . . ROCE-2 + |
| |
| Channel ID . . . . . . . . . . . 100 + |
| Port . . . . . . . . . . . . . . 1 + |
| Virtual Function ID . . . . . . 3__ + |
| Number of virtual functions . . 1 |
| UID . . . . . . . . . . . . . . ____ |
| |
| Description . . . . . . . . . . RoCE-2 FID=00A2 VFID=3 CHID=100_ |
| |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------- Add/Modify Physical Network IDs ---------------------*
| |
| |
| If the Channel ID (CHID) is associated to one or more physical networks, |
| specify each physical network ID corresponding to each applicable |
| physical port. |
| |
| Physical network ID 1 . . PERFNET |
| Physical network ID 2 . . ________________ |
| Physical network ID 3 . . ________________ |
| Physical network ID 4 . . ________________ |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------------- Define Access List ----------------------------*
| Row 22 of 31 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one partition for the access list. |
| |
| Function ID . . . . : 00A2 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 1 MUSCA11 1 OS |
| _ 1 MUSCA12 2 OS |
| _ 1 MUSCA13 3 OS |
| _ 1 MUSCA14 4 OS |
| _ 1 MUSCA15 5 OS |
| _ 1 MUSCA16 6 OS |
| _ 1 MUSCA17 7 OS |
| _ 1 MUSCA18 8 OS |
| _ 1 MUSCA19 9 OS |
| _ 2 MUSCA2A A CF MUSCA2A test CF partition |
| **************************** Bottom of data ***************************** |
| |
| |
*---------------------------------------------------------------------------*
|
PCIe Function List Row 7 of 24 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 00A2 100 1 3 ROCE-2 ____ RoCE-2 FID=00A2 VFID=3 CHID=100
|
PCIe Function List Row 7 of 24 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 00A2 100 1 3 ROCE-2 ____ RoCE-2 FID=00A2 VFID=3 CHID=100
_ 00A3 100 2 4 ROCE-2 ____ RoCE-2 FID=00A3 VFID=4 CHID=100
_ 00B2 160 1 3 ROCE-2 ____ RoCE-2 FID=00B2 VFID=3 CHID=160
_ 00B3 160 2 4 ROCE-2 ____ RoCE-2 FID=00B3 VFID=4 CHID=160
|
Processor List Row 1 of 3 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more processors, then press Enter. To add, use F11.
/ Proc. ID Type + Model + Mode+ Serial-# + Description
_ CETUS 3906 M03 LPAR 0EE0F73906 Cetus
_ LEPUS 2965 N20 LPAR 0BB4B72965 Lepus
f MUSCA 3907 ZR1 LPAR 007A883907 Musca
|
PCIe Function List
Command ===> add____________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
|
*---------------------------- Add PCIe Function ----------------------------*
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| |
| Function ID . . . . . . 00C1 |
| Type . . . . . . . . . ZEDC-EXPRESS + |
| |
| Channel ID . . . . . . . . . . . 120 + |
| Port . . . . . . . . . . . . . . _ + |
| Virtual Function ID . . . . . . 2 + |
| Number of virtual functions . . 1 |
| UID . . . . . . . . . . . . . . ____ |
| |
| Description . . . . . . . . . . zEDC FID=00C1 VFID=2 CHID=120 |
| |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------------- Define Access List ----------------------------*
| Row 22 of 31 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one partition for the access list. |
| |
| Function ID . . . . : 00C1 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 1 MUSCA11 1 OS |
| _ 1 MUSCA12 2 OS |
| _ 1 MUSCA13 3 OS |
| _ 1 MUSCA14 4 OS |
| _ 1 MUSCA15 5 OS |
| _ 1 MUSCA16 6 OS |
| _ 1 MUSCA17 7 OS |
| _ 1 MUSCA18 8 OS |
| _ 1 MUSCA19 9 OS |
| _ 2 MUSCA2A A CF MUSCA2A test CF partition |
| **************************** Bottom of data ***************************** |
| |
| |
*---------------------------------------------------------------------------*
|
PCIe Function List Row 14 of 23 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 00C1 120 _ 2 ZEDC-EXPRESS ____ zEDC FID=00C1 VFID=2 CHID=120
|
PCIe Function List Row 14 of 24 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 00C1 120 _ 2 ZEDC-EXPRESS ____ zEDC FID=00C1 VFID=2 CHID=120
_ 00D1 140 _ 2 ZEDC-EXPRESS ____ zEDC FID=00D1 VFID=2 CHID=140
|
Processor List Row 1 of 3 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more processors, then press Enter. To add, use F11.
/ Proc. ID Type + Model + Mode+ Serial-# + Description
_ CETUS 3906 M03 LPAR 0EE0F73906 Cetus
_ LEPUS 2965 N20 LPAR 0BB4B72965 Lepus
f MUSCA 3907 ZR1 LPAR 007A883907 Musca
|
PCIe Function List
Command ===> add____________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
|
*---------------------------- Add PCIe Function ----------------------------*
| |
| |
| Specify or revise the following values. |
| |
| Processor ID . . . . : MUSCA Musca |
| |
| Function ID . . . . . . 0102 |
| Type . . . . . . . . . ZHYPERLINK + |
| |
| Channel ID . . . . . . . . . . . 108 + |
| Port . . . . . . . . . . . . . . 1 + |
| Virtual Function ID . . . . . . 3__ + |
| Number of virtual functions . . 1 |
| UID . . . . . . . . . . . . . . ____ |
| |
| Description . . . . . . . . . . zHYP FID=0102 VFID=3 CHID=108___ |
| |
| |
*---------------------------------------------------------------------------*
|
*--------------------------- Define Access List ----------------------------*
| Row 22 of 31 |
| Command ===> _________________________________________ Scroll ===> CSR |
| |
| Select one partition for the access list. |
| |
| Function ID . . . . : 0102 |
| |
| / CSS ID Partition Name Number Usage Description |
| / 1 MUSCA11 1 OS |
| _ 1 MUSCA12 2 OS |
| _ 1 MUSCA13 3 OS |
| _ 1 MUSCA14 4 OS |
| _ 1 MUSCA15 5 OS |
| _ 1 MUSCA16 6 OS |
| _ 1 MUSCA17 7 OS |
| _ 1 MUSCA18 8 OS |
| _ 1 MUSCA19 9 OS |
| _ 2 MUSCA2A A CF MUSCA2A test CF partition |
| **************************** Bottom of data ***************************** |
| |
| |
*---------------------------------------------------------------------------*
|
PCIe Function List Row 19 of 21 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 0102 108 1 3 ZHYPERLINK ____ zHYP FID=0102 VFID=3 CHID=108
|
PCIe Function List Row 13 of 24 More:
Command ===> _______________________________________________ Scroll ===> CSR
Select one or more PCIe functions, then press Enter. To add, use F11.
Processor ID . . . . : MUSCA Musca
/ FID CHID+ P+ VF+ Type+ UID Description
_ 0102 108 1 3 ZHYPERLINK ____ zHYP FID=0102 VFID=3 CHID=108
_ 0103 108 2 4 ZHYPERLINK ____ zHYP FID=0103 VFID=4 CHID=108
_ 0202 168 1 3 ZHYPERLINK ____ zHYP FID=0202 VFID=3 CHID=168
_ 0203 168 2 4 ZHYPERLINK ____ zHYP FID=0203 VFID=4 CHID=168
|