Feature codes and RPQ
This appendix lists all feature codes (FC) and requests for price quotation (RPQs) that are related to the installation of IBM TS7700. It provides several quick-reference lists.
Exception: This appendix provides a general description of feature codes and to where they apply. Use the following link to the IBM Product IBM Knowledge Center for technical information related to the TS7700:
|
This appendix includes the following sections:
RPQ
This section describes any RPQs that are available for the TS7700 according to component, machine type, and model.
3952 F05 RPQ
Available by RPQ is the ability for top exit as it relates to cables in the 3952 F5 frame. An example is SCORE RPQ 649-26263.
Feature code lists
This section lists feature code descriptions for the TS7700 according to component, machine type, and model.
Clarification: The symbol “†” means that the specific feature has been withdrawn.
|
3952 F05 features
The features are as follows:
•FC 1903, Dual AC power
•FC 1904, Redundant AC power
•FC 2704, Console Expansion 26 Port Switch
•FC 2719, Console upgrade†
•FC 2725, TS3500 System Console Rackmount
•FC 2730, TS3000 System Console†
•FC 2732, TS3000 System Console†
•FC 2733, Internal modem†
•FC 4743, Remove 3957-VA/VEA
•FC 5512, TS3000 System Console KVM keyboard, video, and mouse
•FC 5626, Plant install 3957-VEA†
•FC 5627, Install 3957-VEB
•FC 5628, Plant install 3957-V06†
•FC 5629, Install 3957-V07
•FC 5635, Plant install 3956-CS8†
•FC 5636, Plant install 3956-CS7†
•FC 5638, Plant install 3956-CC6†
•FC 5639, Plant install 3956-CC7†
•FC 5640, Plant install 3956-CC8†
•FC 5641, Plant install 3956-CX7†
•FC 5642, Field install 3956-CX7†
•FC 5646, Plant install 3956-XS7†
•FC 5647, Field install 3956-Xi
•FC 5648, Plant install 3956-CX6†
•FC 5649, Field install 3956-CX6†
•FC 5651, Plant install 3956-CZ
•FC 5652, Plant install 3956-CD
•FC 5653, Plant install 3956-Cox
•FC 5654, Field install 3956-Cox
•FC 5655, Plant install 3956-Xi
•FC 5656, Field install 3956-Xi
•FC 5758, Integrated control path
•FC 5759, Integrated control path†
•FC 7312, TS7740 Base frame †
•FC 7322, TS7720 Base frame †
•FC 7323, TS7720 Storage expansion frame†
•FC 7330, TS7740 Encryption Capable base frame
•FC 7331, TS7720 Encryption Capable base frame
•FC 7332, TS7720 Encryption Capable expansion frame
•FC 9110, Ship with R1.7 machine code†
•FC 9111, Ship with R2.0 machine code†
•FC 9112, Ship with R2.1 machine code†
•FC 9113, ship with R3.0 machine code†
•FC 9114, Ship with R3.1 machine code†
•FC 9115, Ship with R3.2 machine code†
•FC 9116, Ship with R3.3 machine code
•FC 9323, Expansion frame attachment
•FC 9954, NEMA L6-30 power cord
•FC 9955, RS 9750 DP power cord
•FC 9956, IEC 309 power cord
•FC 9957, PDL 4.3 power cord
•FC 9958, Korean 4.3-m power cord
•FC 9959, Unterminated power cord
•FC 9966, Unterminated power cord (China)
Server features for 3957-V06, 3957-V07, 3957-VEA, and 3957-VEB
This section lists the server features for 3957-V06, 3957-V07, 3957-VEA, and 3957-VEB.
3957-V06 Server features†
•FC 0201, 9-micron LC/LC 31-meter
•FC 0202, 9-micron LC/SC 31-meter†
•FC 0203, 50-micron LC/LC 31-meter
•FC 0204, 50-micron LC/SC 31-meter†
•FC 0205, 62.5-micron LC/LC 31-meter†
•FC 0206, 62.5-micron LC/SC 31-meter†
•FC 0521, Functional enhancement field
•FC 1030, 1-Gb grid copper connection†
•FC 1031, 1-Gb optical SW connection†
•FC 1032, 1-Gb grid dual port copper connection
•FC 1033, 1-Gb grid dual port optical SW connection
•FC 1034, Enable dual port grid connection
•FC 2714, Console expansion†
•FC 2715, Console attachment
•FC 2719, Console upgrade†
•FC 2720, TS3000 System Console†
•FC 3441, FICON short-wavelength attachment
•FC 3442, FICON long-wavelength attachment
•FC 3443, FICON 10-km long-wavelength attachment
•FC 3461, 8 GB Memory upgrade, field
•FC 4015, Grid enablement
•FC 4016, Remove cluster from grid
•FC 4017, Cluster cleanup
•FC 5240, Dual port Fibre Channel host bus adapter†
•FC 5267, 1 TB cache enablement
•FC 5268, 100 MiB/Sec increment
•FC 5270, Increased logical volume
•FC 5271, Selective Device Access Control (SDAC)
•FC 9000, Mainframe attachment†
•FC 9217, Attach to 3953 LM†
•FC 9218, Attach to 3494 LM†
•FC 9219, Attach to TS3500†
•FC 9350, Plant install TS7700 Server in 3952 F05†
•FC 9351, Field merge 3957-V06 in 3952 F05
•FC 9461, 8 GB Memory upgrade, plant†
•FC 9700, No factory cables†
•FC 9900, Encryption configuration
3957-V07 Server features
•FC 0201, 9-micron LC/LC 31-meter
•FC 0203, 50-micron LC/LC 31-meter
•FC 1034, Enable dual port grid connection
•FC 1035, 10 Gb Grid optical LW connection
•FC 1036, 1 Gb grid dual port copper connection
•FC 1037, 1 Gb grid dual port optical sw connection
•FC 2714, Console expansion†
•FC 2715, Console attachment
•FC 3401, Enable 8 Gb FICON second port
•FC 3438, 8 Gb FICON Short Wavelength Attachment
•FC 3439, 8 Gb FICON Long Wavelength Attachment
•FC 3441, FICON short-wavelength attachment
•FC 3442, FICON long-wavelength attachment
•FC 3443, FICON 10-km long-wavelength attachment
•FC 3462 Memory Upgrade
•FC 4015, Grid enablement
•FC 4016, Remove cluster from grid
•FC 4017, Cluster cleanup
•FC 5241, Dual port FC HBA
•FC 5267, 1 TB cache enablement
•FC 5268, 100 MiB/Sec increment
•FC 5270, Increased logical volumes
•FC 5271, SDAC
•FC 5272, Enable Disk Encryption
•FC 5275, Additional virtual devices
•FC 5276, Enable disk encryption - External Key Management
•FC 5277, External Disk Encryption Certificate - Field
•FC 9000, Mainframe attachment
•FC 9111, Ship with R2.0 machine code†
•FC 9112, Ship with R2.1 machine code†
•FC 9113, Ship with R3.0 machine code†
•FC 9114, Ship with R3.1 machine Code†
•FC 9115, Ship with R3.2 machine Code†
•FC 9116, Ship with R3.3 machine Code
•FC 9219, Attach to TS3500
•FC 9277, External Disk Encryption Certificate - Plant
•FC 9350, Plant install TS7700 Server in 3952 F05†
•FC 9351, Field merge TS7700 Server in 3952 F05
•FC 9700, No factory cables†
•FC 9900, Encryption configuration
3957-VEA Server features†
•FC 0201, 9-micron LC/LC 31-meter
•FC 0202, 9-micron LC/SC 31-meter†
•FC 0203, 50-micron LC/LC 31-meter
•FC 0204, 50-micron LC/SC 31-meter†
•FC 0205, 62.5-micron LC/LC 31-meter†
•FC 0206, 62.5-micron LC/SC 31-meter†
•FC 0521, Functional enhancement field
•FC 1032, 1 Gb grid dual port copper connection
•FC 1033, 1 Gb grid dual port optical SW connection
•FC 1034, Enable dual port grid connection
•FC 2714, Console expansion†
•FC 2715, Console attachment
•FC 3441, FICON short-wavelength attachment
•FC 3442, FICON long-wavelength attachment
•FC 3443, FICON 10-km long-wavelength attachment
•FC 3461, 8 GB Memory upgrade, field
•FC 4015, Grid enablement
•FC 4016, Remove cluster from grid
•FC 4017, Cluster cleanup
•FC 5240, Dual port Fibre Channel host bus adapter†
•FC 5268, 100 MiB/Sec increment
•FC 5270, Increased logical volumes
•FC 5271, SDAC
•FC 9000, Mainframe attachment†
•FC 9268, Plant install 100 MiB/Sec throughput†
•FC 9350, Plant install TS7700 Server in 3952 F05†
•FC 9461, 8 GB Memory upgrade, plant†
•FC 9700, No factory cables†
3957-VEB Server features
•FC 0201, 9-micron LC/LC 31-meter
•FC 0203, 50-micron LC/LC 31-meter
•FC 1034, Enable dual port grid connection
•FC 1035, 10 Gb Grid optical LW connection
•FC 1036, 1 Gb grid dual port copper connection
•FC 1037, 1 Gb dual port optical SW connection
•FC 2714, Console expansion†
•FC 2715, Console attachment
•FC 3401, Enable 8 Gb FICON second port
•FC 3438, 8 Gb FICON Short Wavelength Attachment
•FC 3439, 8 Gb FICON Long Wavelength Attachment
•FC 3441, FICON short-wavelength attachment
•FC 3442, FICON long-wavelength attachment
•FC 3443, FICON 10-km long-wavelength attachment
•FC 3462, Memory Upgrade
•FC 4015, Grid enablement
•FC 4016, Remove cluster from grid
•FC 4017, Cluster cleanup
•FC 5241, Dual port FC HBA
•FC 5268, 100 MiB/Sec increment
•FC 5270, Increased logical volumes
•FC 5271, SDAC
•FC 5272, Enable Disk Encryption
•FC 5273, Enable TS7720 Tape Attach (mandatory for TS7720T, not applicable to 3-frame TS7720 with CS8 based expansion frame)
•FC 5274, 1 TB Active Premigration Capacity (mandatory for TS7720T, minimum qty 1, maximum qty 10)
•FC 5276, Enable disk encryption - External Key Management
•FC 5277, External Disk Encryption Certificate - Field
•FC 5275, Additional virtual devices
•FC 9000, Mainframe attachment
•FC 9111, Ship with R2.0 machine code†
•FC 9112, Ship with R2.1 machine code†
•FC 9113, Ship with R3.0 machine code†
•FC 9114, Ship with R3.1 machine code†
•FC 9115, Ship with R3.2 machine code†
•FC 9116, Ship with R3.3 machine Code
•FC 9219, TS3500 Attach (mandatory for TS7720T and requires two FC switches with
4 - 16 3592 tape drives)
•FC 9268, Plant install 100 MiB/Sec throughput
•FC 9277, External Disk Encryption Certificate - Plant
•FC 9350, Plant install TS7700 Server in 3952 F5
•FC 9351, Field merge TS7700 Server in 3952 F05
•FC 9700, No factory cables
•FC 9900, Tape Encryption Enablement - optional for TS7720T
Cache Controller features for 3956-CC7, 3956-CC8, 3956-CC9, and 3956-CS9
Feature codes that are available for the TS7700 3956 cache controller are listed by model.
Clarification: The symbol “†” means that specific feature has been withdrawn.
|
3956-CC7† Cache Controller features
•FC 7121, 3.43 TB Fibre storage†
•FC 7113, 16 TB SATA storage†
•FC 7403, Enable first expansion drawer†
•FC 7404, Enable fourth expansion drawer†
•FC 9352, Plant install a TS7700 Cache Controller in a 3952 F05†
•FC 9353, Field merge in 3952 F05†
3956-CC8† Cache Controller features
The features are as follows:
•FC 7123, 9.6 TB Fibre storage†
•FC 7403, Enable first expansion drawer†
•FC 9352, Plant install a TS7700 Cache Controller in a 3952 F05†
3956-CC9 Encryption Capable Cache Controller Drawer features
•FC 7124, 13.2 TB SAS Storage
•FC 7404, Encryption plant or field
•FC 9352, Plant install a TS7740 Encryption Capable Cache Controller Drawer in a 3952 F05
3956-CS9 Encryption Capable Cache Controller Drawer features
•FC 7115, 36 TB SAS Storage
•FC 7404, Encryption plant or field
•FC 9352, Plant install a TS7720 Encryption Capable Cache Controller Drawer in a 3952 F05
TS7700 Cache Drawer features 3956-CX7, 3956-XS7, 3956-CS8, 3956-CX9, and 3956-XS9
Feature codes available for the Cache Drawer are listed by model in this section.
Clarification: The symbol “†” means that specific feature has been withdrawn.
|
3956-CX7† Cache Drawer features
•FC 7123, 9.6 TB Fibre storage†
•FC 9354, Plant install a TS7700 Cache Drawer in a 3952 F05†
•FC 9355, Field merge a TS7700 Cache Drawer in a 3952 F05
3956-XS7† Cache Drawer features
•FC 7113, 16 TB SATA storage†
•FC 7114, 32 TB SATA storage†
•FC 9354, Plant install a TS7700 Cache Drawer in a 3952 F05†
•FC 9355, Field merge a TS7700 Cache Drawer in a 3952 F05
3956-CS8† Cache Drawer features
•FC 7114, 32 TB SATA storage†
•FC 9352, Plant install a TS7700 Cache Controller in a 3952 F05†
3956-CX9 Encryption Capable Cache Expansion Drawer features
•FC 7124, 13.2 TB SAS Storage
•FC 7404, Encryption plant or field
•FC 9354, Plant install a TS7740 Encryption Capable Cache Expansion Drawer in a 3952 F05
•FC 9355, Field merge a TS7740 Encryption Capable Cache Expansion Drawer in a 3952 F05
3956-XS9 Encryption Capable Cache Expansion Drawer features
•FC 7116, 33 TB SAS Storage
•FC 7404, Encryption plant or field
•FC 9354, Plant install a TS7720 Encryption Capable Cache Expansion Drawer in a 3952 F05
•FC 9355, Field merge a TS7720 Encryption Capable Cache Expansion Drawer in a 3952 F05